NGI Technologies Company Limited
Modul de sursă DC programabil seria NXI-3106

Acasă>Produse>Instrumente modulare>Achiziție și măsurare a datelor>Alimentare

Modul de sursă DC programabil seria NXI-3106
Modul de sursă DC programabil seria NXI-3106

Modul de sursă DC programabil seria NXI-3106


NXI-3106 series is a programmable DC power supply module with high power density, high accuracy. Single card with single  slot, output power up to 60W. NXI-3106 supports independent single card /integrated control, supports CC, CV and SEQ  modes, CC&CV priority selection function, widely used in integrated test systems, large-scale production line testing and  other test scenarios.

Distribuiți către:
Caracteristici principale

●Interval de putere 0~60W

●Interval de tensiune 6V/15V/30V/60V

●Interval de curent 12A/4A/2A/1A

● Suportă modul CC/CV

● Suportă funcția SEQ, 1000 de pași pentru un total de 10 fișiere, care pot fi auto-alocate

● Suport integrat cu șasiul de măsurare și control NXI-F1080, NXI-F1030, NXI-F1020

● Suportă funcția de selecție a priorităților CC&CV

● Suportă protecție OVP/OCP/OPP/OTP

●Latime 4CP pentru un singur modul

● Intrare 220V AC, suportă controlul comunicațiilor portului LAN

Funcții și avantaje

Integrare ridicată, șasiu 4U acceptă până la 16 canale
NXI-3106 programmable DC power supply module can be Integrated used with NXI-F1080 series and other measurement & control system chassis, a single chassis supports up to 16 channels. Compare to general desktop power supply, the  ultra-high integration effectively help users to save the space and cost of test.
NXI3106 4U 16 canale de înaltă integrare

Funcția SEQ
NXI-3106 series supports SEQ mode, and it can be edited in up to 1000 steps, users can set output voltage, output current,  and single step dwell time.
Funcția NXI3106 SEQ

Funcția de prioritate CC&CV
NXI-3106 series supports CC&CV priority function, users  can choose the optimal working mode for testing according  to the characteristics of DUT. As shown in Figure 1, when the DUT needs to avoid voltage  overshoot during testing,the voltage priority mode should be  used to obtain a fast and smooth rise voltage.  As shown in Figure 2, when the DUT needs to avoid the  current overshoot, or the DUT is low impedance, the current  priority mode should be used to obtain a fast and smooth  rising current.
Funcția de prioritate CC&CV NXI3106

Baza de date

  • Fișa cu date
  • Manual de utilizare
  • Protocol de comunicare
  • Software și driver
  • Aplicatii
Anchetă

Categorii fierbinți